Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| concentration not stated | D | D |
Material comparison at 20 °C
Resistance overview
EPDM is not resistant (D) to Acrylonitrile and should not be used in direct contact. The chemical is expected to cause rapid degradation, which can include dissolution, cracking, severe swelling, or complete structural failure of the material.
Application context
Acrylonitrile is commonly encountered in electronics cleaning and chemical synthesis. EPDM (Ethylene propylene diene rubber) is an elastomer typically used for seals, O-rings, hoses and flexible connections. Since Acrylonitrile is flammable, material selection must also consider the risk of static charge buildup and the need for proper grounding in storage and transfer systems.
Practical recommendation
EPDM is not recommended for use with Acrylonitrile. The D rating indicates that the material will suffer rapid and severe degradation, which may include cracking, dissolution, severe swelling, or complete structural failure. Using this combination risks equipment damage, leaks, and potential safety incidents. Consider using HDPE, LDPE, Nylon (PA) instead, which are rated A for this chemical and offer reliable long-term performance.
Did you know?
Temperature is often the deciding factor when selecting materials for Acrylonitrile: even materials rated A at 20 °C may lose performance at elevated temperatures.
Materials rated A or B at 20 °C
- Thermoplastics
- HDPE A, LDPE A, Nylon (PA) A
- Fluoropolymers
- PTFE A, FEP A, ECTFE/ETFE A
- Metals
- SS 316 A, SS 304 A, Aluminium A
About EPDM
EPDM resists water, steam, alkalis, ketones and alcohols. Mineral oils, fuels and aromatic solvents swell it severely.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.