Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| 50 % | A | – | |
| aqueous | A* | – |
* estimated rating, given in the source without a temperature
Material comparison at 20 °C
Resistance overview
Polycarbonate shows excellent resistance to Calcium Nitrate across all 2 tested concentrations (50 %, aqueous) at 20 °C, making it a reliable choice for storage, transfer, and handling applications involving this chemical at any of the tested strengths. The rating remains stable between 20 °C and 50 °C, which means this material can also handle moderately elevated process temperatures without additional risk.
Application context
Calcium Nitrate is commonly encountered in water treatment and electroplating. Polycarbonate (Polycarbonate) is a thermoplastic typically used for tanks, piping, containers and liners. The compatibility between these two is therefore an important consideration for engineers and procurement teams selecting containment, transfer, or processing equipment.
Practical recommendation
Polycarbonate can be used with confidence for Calcium Nitrate containment and handling. The A rating indicates that the material shows no significant change in weight, dimensions, or mechanical properties after prolonged contact under test conditions. This holds true at both 20 °C and 50 °C, giving a good safety margin for typical process environments.
Did you know?
Chemical resistance testing according to DIN and ISO standards typically evaluates weight change, dimensional change, and retention of tensile strength after immersion.
Materials rated A or B at 20 °C
Based on the row for 50 %, 20 °C.
- Thermoplastics
- HDPE A, PP A, PVC Rigid A, LDPE A, Nylon (PA) B, PVC Flexible A, Polystyrene A, PETG B, PMP A
- Fluoropolymers
- PTFE A, PVDF A, FEP A
- Elastomers
- EPDM A, Viton (FPM) A
- Metals
- SS 316 A, SS 304 A, Aluminium A
About Polycarbonate
Polycarbonate is attacked by alkalis, amines, ketones, esters and many organic solvents, and it stress-cracks under load in contact with them.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.