Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| technical grade | C | – |
Material comparison at 20 °C
Resistance overview
HDPE has limited resistance (C) to Chloromethane (Methyl Chloride) at technical grade at 20 °C. This indicates that the chemical has a noticeable effect on the material, which may include visible swelling, softening, or a measurable loss of tensile strength. Use is generally limited to short-term or intermittent contact where full structural integrity is not required. The rating remains stable between 20 °C and 50 °C, which means this material can also handle moderately elevated process temperatures without additional risk.
Application context
Chloromethane (Methyl Chloride) is commonly encountered in chemical processing and bleaching. HDPE (High-density polyethylene) is a thermoplastic typically used for tanks, piping, containers and liners. Since Chloromethane (Methyl Chloride) is flammable, material selection must also consider the risk of static charge buildup and the need for proper grounding in storage and transfer systems.
Practical recommendation
HDPE has limited resistance to Chloromethane (Methyl Chloride) and should only be used for short-term or intermittent contact at ambient temperature. The C rating means the material undergoes noticeable changes — swelling, loss of strength, or surface degradation — that make it unsuitable for permanent installations. For prolonged or continuous exposure, Acetal (POM), FEP, PTFE offer significantly better resistance and are rated A.
Did you know?
When choosing between thermoplastics for Chloromethane (Methyl Chloride) service, engineers consider not just the resistance rating but also factors such as permeation rate, creep resistance, and weldability.
Materials rated A or B at 20 °C
Based on the row for technical grade, 20 °C.
- Thermoplastics
- LDPE B, Acetal (POM) A
- Fluoropolymers
- PTFE A, PVDF A, FEP A
- Metals
- SS 316 A, SS 304 A
About HDPE
High-density polyethylene resists most aqueous acids, alkalis and salt solutions. Strong oxidising acids, chlorinated solvents and aromatic hydrocarbons attack or swell it. Continuous service is usually limited to about 80 °C.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.