Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| 10 % | A | – |
Material comparison at 20 °C
Resistance overview
LDPE shows very good resistance (A) to Hydrazine at 10 % at 20 °C, meaning the material remains essentially unaffected by this chemical under standard laboratory test conditions. The rating remains stable between 20 °C and 50 °C, which means this material can also handle moderately elevated process temperatures without additional risk.
Application context
Hydrazine is commonly encountered in chemical synthesis and coatings and paints. LDPE (Low-density polyethylene) is a thermoplastic typically used for tanks, piping, containers and liners. Since Hydrazine is flammable, material selection must also consider the risk of static charge buildup and the need for proper grounding in storage and transfer systems.
Practical recommendation
LDPE can be used with confidence for Hydrazine containment and handling. The A rating indicates that the material shows no significant change in weight, dimensions, or mechanical properties after prolonged contact under test conditions. This holds true at both 20 °C and 50 °C, giving a good safety margin for typical process environments.
Did you know?
The ratings shown here apply to pure Hydrazine in contact with the base thermoplastic. In real-world applications, additives, pigments, and fillers in the material can shift resistance in either direction.
Materials rated A or B at 20 °C
Based on the row for 10 %, 20 °C.
- Thermoplastics
- HDPE A, PP A, PVC Rigid A, Acetal (POM) B
- Fluoropolymers
- PTFE A, PVDF A, FEP A
- Elastomers
- EPDM A
- Metals
- SS 316 A, SS 304 A, Aluminium A
About LDPE
Low-density polyethylene has a similar profile to HDPE but is softer and more permeable, so solvents swell it sooner. Continuous service is usually limited to about 60 °C.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.