ChemicalResistance ChemicalResistance.org ← Search
Home Chemicals Palmitic Acid Stainless Steel 304

Palmitic Acid Resistance of Stainless Steel 304

Is Stainless Steel 304 compatible with Palmitic Acid?

Compatibility Rating

At 20°C
A
Excellent
Excellent resistance - recommended for continuous use
At 50°C
A
Excellent
Excellent resistance - recommended for continuous use

Why is SS 304 resistant to Palmitic Acid?

SS 304 shows excellent resistance to Palmitic Acid due to its chromium content (18%) forming a passive oxide layer resistant to many corrosive environments.

⚠️ When NOT to use SS 304

Avoid using Stainless Steel 304 with chloride-rich environments (seawater, HCl) which cause pitting corrosion. Use 316 grade for chloride exposure.

Comparison Table — All Materials for Palmitic Acid

Material20°C50°C
HDPECC
LDPEBB
PPCD
PTFEAA
PVDFAA
FEPAA
ECTFE/ETFENRNR
EPDMDD
Viton (FPM)AA
NBRCC
SiliconeNRNR
SS 316AA
SS 304AA
AluminiumAA
PVC RigidAA
PVC FlexibleCNR
PMPNRNR
PolystyreneAA
SANAA
PolycarbonateBB
PETGANR
Acetal (POM)ANR
Nylon (PA)AA
PolysulfoneNRNR

A=Excellent · B=Good · C=Fair · D=Poor · NR=No Data

🌡️ Temperature Note

Good resistance at both 20°C and 50°C. Maximum service temperature for this material is 800°C — above this, degradation risk increases significantly.

🔄 Better Alternative?

Consider: SS 316 for chloride environments. View all materials for Palmitic Acid →

FAQ

Is Stainless Steel 304 resistant to Palmitic Acid?

Stainless Steel 304 has Excellent (A) resistance to Palmitic Acid at 20°C.

Can I store Palmitic Acid in Stainless Steel 304?

Yes, Stainless Steel 304 is rated A for Palmitic Acid.

All Materials for Palmitic Acid All Chemicals for Stainless Steel 304