LDPE and Potassium Bromate: Chemical Resistance

Low-density polyethylene

Rating

Concentration20 °C50 °CRemark
aqueous––
saturatedAC

Material comparison at 20 °C

Potassium Bromate: Material comparison at 20 °CLDPE: A (highlighted); EPDM: A; FEP: A; Viton (FPM): A; HDPE: A; NBR: A.EPDM: AFEP: AViton (FPM): AHDPE: ALDPE: ALDPENBR: APolycarbonate: APP: APolystyrene: APTFE: APVC Rigid: APVDF: ASAN: AAluminium: BNylon (PA): BAcetal (POM): BECTFE/ETFE: –PETG: –PMP: –Polysulfone: –PVC Flexible: –Silicone: –SS 304: –SS 316: –
A very good resistanceB good resistanceC limited resistanceD not resistantno data
Each bar is one material. Taller bars indicate better resistance. The highlighted bar is the current material.

Resistance overview

LDPE shows very good resistance (A) to Potassium Bromate at saturated at 20 °C, meaning the material remains essentially unaffected by this chemical under standard laboratory test conditions. However, at 50 °C the resistance rating drops, indicating that temperature must be factored into the design. For heated applications, additional testing under actual service conditions is strongly recommended.

Application context

Potassium Bromate is commonly encountered in water disinfection and waste treatment. LDPE (Low-density polyethylene) is a thermoplastic typically used for tanks, piping, containers and liners. The compatibility between these two is therefore an important consideration for engineers and procurement teams selecting containment, transfer, or processing equipment.

Practical recommendation

LDPE can be used with confidence for Potassium Bromate containment and handling. The A rating indicates that the material shows no significant change in weight, dimensions, or mechanical properties after prolonged contact under test conditions. At elevated temperatures (50 °C), some reduction in resistance occurs, so periodic inspection is advisable for heated applications. Always verify performance under actual operating conditions before committing to a design.

Did you know?

The ratings shown here apply to pure Potassium Bromate in contact with the base thermoplastic. In real-world applications, additives, pigments, and fillers in the material can shift resistance in either direction.

Materials rated A or B at 20 °C

Based on the row for saturated, 20 °C.

Thermoplastics
HDPE A, PP A, PVC Rigid A, Nylon (PA) B, Acetal (POM) B, Polycarbonate A, Polystyrene A, SAN A
Fluoropolymers
PTFE A, PVDF A, FEP A
Elastomers
EPDM A, Viton (FPM) A, NBR A
Metals
Aluminium B

About LDPE

Low-density polyethylene has a similar profile to HDPE but is softer and more permeable, so solvents swell it sooner. Continuous service is usually limited to about 60 °C.

Rating scale

A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.

About this data

The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.

A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.