Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| 40 % | A* | – | |
| technical grade | A* | – |
* estimated rating, given in the source without a temperature
Material comparison at 20 °C
Resistance overview
Aluminium shows excellent resistance to Acetaldehyde across all 2 tested concentrations (40 %, technical grade) at 20 °C, making it a reliable choice for storage, transfer, and handling applications involving this chemical at any of the tested strengths. The rating remains stable between 20 °C and 50 °C, which means this material can also handle moderately elevated process temperatures without additional risk.
Application context
Acetaldehyde is commonly encountered in chemical synthesis and coatings and paints. Aluminium (Aluminium) is a metal typically used for vessels, heat exchangers, fittings and structural components. Since Acetaldehyde is flammable, material selection must also consider the risk of static charge buildup and the need for proper grounding in storage and transfer systems.
Practical recommendation
Aluminium can be used with confidence for Acetaldehyde containment and handling. The A rating indicates that the material shows no significant change in weight, dimensions, or mechanical properties after prolonged contact under test conditions. This holds true at both 20 °C and 50 °C, giving a good safety margin for typical process environments.
Did you know?
Aluminium is commonly chosen for vessels, heat exchangers, fittings and structural components because of its combination of chemical resistance, mechanical strength, and cost-effectiveness.
Materials rated A or B at 20 °C
Based on the row for 40 %, 20 °C.
- Thermoplastics
- LDPE B, Nylon (PA) B, Acetal (POM) B, PMP B
- Fluoropolymers
- PTFE A, FEP A, ECTFE/ETFE B
- Metals
- SS 316 A, SS 304 A
About Aluminium
Aluminium relies on a thin oxide layer. Strong acids, strong alkalis and mercury compounds destroy that layer.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.