Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| 5 % | A | A | |
| 10 % | A | A | |
| 50 % | A | A | |
| 90 % | A | B | |
| 100 % | A | C |
Material comparison at 20 °C
Resistance overview
PP shows excellent resistance to Acetic Acid across all 5 tested concentrations (5 %, 10 %, 50 %, 90 %, 100 %) at 20 °C, making it a reliable choice for storage, transfer, and handling applications involving this chemical at any of the tested strengths. However, at 50 °C the resistance rating drops, indicating that temperature must be factored into the design. For heated applications, additional testing under actual service conditions is strongly recommended.
Application context
Acetic Acid is commonly encountered in laboratory work and water treatment. PP (Polypropylene) is a thermoplastic typically used for tanks, piping, containers and liners. Because Acetic Acid is classified as corrosive, the choice of containment material is especially critical to prevent leaks, equipment damage, and safety hazards.
Practical recommendation
PP can be used with confidence for Acetic Acid containment and handling. The A rating indicates that the material shows no significant change in weight, dimensions, or mechanical properties after prolonged contact under test conditions. At elevated temperatures (50 °C), some reduction in resistance occurs, so periodic inspection is advisable for heated applications. Always verify performance under actual operating conditions before committing to a design.
Did you know?
When choosing between thermoplastics for Acetic Acid service, engineers consider not just the resistance rating but also factors such as permeation rate, creep resistance, and weldability.
Materials rated A or B at 20 °C
Based on the row for 90 %, 20 °C.
- Thermoplastics
- HDPE A, PVC Rigid A, LDPE A, PMP A
- Fluoropolymers
- PTFE A, PVDF A, FEP A, ECTFE/ETFE A
- Metals
- SS 316 A, SS 304 A, Aluminium A
About PP
Polypropylene resists most acids, alkalis and salt solutions. Concentrated oxidising acids, chlorinated solvents and aromatic hydrocarbons attack it, and it turns brittle below about 0 °C.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.