Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| aqueous | A | C | |
| concentration not stated | A | C |
Material comparison at 20 °C
Resistance overview
PVC Rigid shows excellent resistance to Arsenic Acid across all 2 tested concentrations (aqueous) at 20 °C, making it a reliable choice for storage, transfer, and handling applications involving this chemical at any of the tested strengths. However, at 50 °C the resistance rating drops, indicating that temperature must be factored into the design. For heated applications, additional testing under actual service conditions is strongly recommended.
Application context
Arsenic Acid is commonly encountered in chemical processing and laboratory work. PVC Rigid (Rigid (unplasticised) polyvinyl chloride) is a thermoplastic typically used for tanks, piping, containers and liners. The compatibility between these two is therefore an important consideration for engineers and procurement teams selecting containment, transfer, or processing equipment.
Practical recommendation
PVC Rigid can be used with confidence for Arsenic Acid containment and handling. The A rating indicates that the material shows no significant change in weight, dimensions, or mechanical properties after prolonged contact under test conditions. At elevated temperatures (50 °C), some reduction in resistance occurs, so periodic inspection is advisable for heated applications. Always verify performance under actual operating conditions before committing to a design.
Did you know?
Temperature is often the deciding factor when selecting materials for Arsenic Acid: even materials rated A at 20 °C may lose performance at elevated temperatures.
Materials rated A or B at 20 °C
Based on the row for aqueous, 20 °C.
- Thermoplastics
- HDPE A, PP A, Polycarbonate A, Polystyrene A
- Fluoropolymers
- PTFE A, PVDF A, FEP A, ECTFE/ETFE A
- Elastomers
- EPDM A, Viton (FPM) B, NBR A
- Metals
- SS 316 A, SS 304 A
About PVC Rigid
Rigid PVC resists acids, alkalis and salt solutions well. Ketones, esters, aromatic and chlorinated solvents dissolve or swell it. Service temperature is limited to about 60 °C.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.