Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| concentration not stated | D | D |
Material comparison at 20 °C
Resistance overview
PVC Rigid is not resistant (D) to Diethyl Ketone and should not be used in direct contact. The chemical is expected to cause rapid degradation, which can include dissolution, cracking, severe swelling, or complete structural failure of the material.
Application context
Diethyl Ketone is commonly encountered in electroplating and de-icing. PVC Rigid (Rigid (unplasticised) polyvinyl chloride) is a thermoplastic typically used for tanks, piping, containers and liners. The compatibility between these two is therefore an important consideration for engineers and procurement teams selecting containment, transfer, or processing equipment.
Practical recommendation
PVC Rigid is not recommended for use with Diethyl Ketone. The D rating indicates that the material will suffer rapid and severe degradation, which may include cracking, dissolution, severe swelling, or complete structural failure. Using this combination risks equipment damage, leaks, and potential safety incidents. Consider using Acetal (POM), FEP, PTFE instead, which are rated A for this chemical and offer reliable long-term performance.
Did you know?
Rigid (unplasticised) polyvinyl chloride was first developed in the 1920s and remains one of the most widely used thermoplastics in chemical handling equipment.
Materials rated A or B at 20 °C
- Thermoplastics
- HDPE B, PP B, LDPE B, Acetal (POM) A, PMP B
- Fluoropolymers
- PTFE A, FEP A, ECTFE/ETFE B
- Metals
- SS 316 A, SS 304 A, Aluminium A
About PVC Rigid
Rigid PVC resists acids, alkalis and salt solutions well. Ketones, esters, aromatic and chlorinated solvents dissolve or swell it. Service temperature is limited to about 60 °C.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.