Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| concentration not stated | B | C |
Material comparison at 20 °C
Resistance overview
Polysulfone shows good but limited resistance (B) to Dioxane at 20 °C. The material can be used in contact with this chemical, but minor effects such as slight swelling or a small reduction in mechanical properties may occur over extended exposure periods. Regular inspection of components in service is advisable. However, at 50 °C the resistance rating drops, indicating that temperature must be factored into the design. For heated applications, additional testing under actual service conditions is strongly recommended.
Application context
Dioxane is commonly encountered in pharmaceutical manufacturing and chemical synthesis. Polysulfone (Polysulfone) is a thermoplastic typically used for tanks, piping, containers and liners. Since Dioxane is flammable, material selection must also consider the risk of static charge buildup and the need for proper grounding in storage and transfer systems.
Practical recommendation
Polysulfone is suitable for use with Dioxane under normal conditions, but some minor effects on the material are expected over time. Periodic monitoring for swelling, softening, or weight change is recommended, especially for long-service components. Avoid prolonged exposure at elevated temperatures, as the resistance decreases further at 50 °C. For safety-critical or long-life applications, consider Nylon (PA), PETG, Acetal (POM) instead, which are rated A for this chemical.
Did you know?
Temperature is often the deciding factor when selecting materials for Dioxane: even materials rated A at 20 °C may lose performance at elevated temperatures.
Materials rated A or B at 20 °C
- Thermoplastics
- HDPE B, LDPE B, Nylon (PA) A, Acetal (POM) A, PETG A, PMP B
- Fluoropolymers
- PTFE A, FEP A, ECTFE/ETFE A
- Elastomers
- EPDM B
- Metals
- SS 316 A, SS 304 A, Aluminium A
About Polysulfone
Polysulfone withstands hot water and steam. Ketones, esters and chlorinated and aromatic solvents attack it.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.