Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| 100 % | D | D |
Material comparison at 20 °C
Resistance overview
Polystyrene is not resistant (D) to Ethyl Acetate at 100 % and should not be used in direct contact. The chemical is expected to cause rapid degradation, which can include dissolution, cracking, severe swelling, or complete structural failure of the material.
Application context
Ethyl Acetate is commonly encountered in electronics cleaning and coatings and paints. Polystyrene (Polystyrene) is a thermoplastic typically used for tanks, piping, containers and liners. Since Ethyl Acetate is flammable, material selection must also consider the risk of static charge buildup and the need for proper grounding in storage and transfer systems.
Practical recommendation
Polystyrene is not recommended for use with Ethyl Acetate. The D rating indicates that the material will suffer rapid and severe degradation, which may include cracking, dissolution, severe swelling, or complete structural failure. Using this combination risks equipment damage, leaks, and potential safety incidents. Consider using HDPE, Nylon (PA), Acetal (POM) instead, which are rated A for this chemical and offer reliable long-term performance.
Did you know?
The ratings shown here apply to pure Ethyl Acetate in contact with the base thermoplastic. In real-world applications, additives, pigments, and fillers in the material can shift resistance in either direction.
Materials rated A or B at 20 °C
Based on the row for 100 %, 20 °C.
- Thermoplastics
- HDPE A, PP A, Nylon (PA) A, Acetal (POM) A
- Fluoropolymers
- PTFE A, FEP A, ECTFE/ETFE A
- Metals
- SS 316 A, SS 304 A, Aluminium A
About Polystyrene
Polystyrene is attacked by most organic solvents, including ketones, esters, aromatic and chlorinated hydrocarbons. It is used for dilute aqueous solutions.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.