ChemicalResistance
ChemicalResistance.org

LDPE and Formaldehyde Solution: Chemical Resistance

Low-density polyethylene

Rating

Concentration20 °C50 °CRemark
10 %AA
30 %AA
40 %BC

Material comparison at 20 °C

Formaldehyde Solution: Material comparison at 20 °CLDPE: B (highlighted); Aluminium: A; ECTFE/ETFE: A; EPDM: A; FEP: A; HDPE: A.Aluminium: AECTFE/ETFE: AEPDM: AFEP: AHDPE: ANylon (PA): APolycarbonate: APETG: APMP: AAcetal (POM): APP: APTFE: APVDF: ASS 304: ASS 316: ALDPE: BLDPEPolysulfone: BPVC Rigid: BViton (FPM): CNBR: CPVC Flexible: CPolystyrene: DSAN: –Silicone: –
A very good resistanceB good resistanceC limited resistanceD not resistantno data
Each bar is one material. Taller bars indicate better resistance. The highlighted bar is the current material.

Resistance overview

The resistance of LDPE to Formaldehyde Solution is concentration-dependent. Across the 3 tested concentrations (10 %, 30 %, 40 %), the 20 °C rating ranges from A at lower concentrations to C at higher ones. This means engineers must verify which concentration their process actually involves before relying on a single rating. However, at 50 °C the resistance rating drops, indicating that temperature must be factored into the design. For heated applications, additional testing under actual service conditions is strongly recommended.

Application context

Formaldehyde Solution is commonly encountered in chemical storage and food processing. LDPE (Low-density polyethylene) is a thermoplastic typically used for tanks, piping, containers and liners. The compatibility between these two is therefore an important consideration for engineers and procurement teams selecting containment, transfer, or processing equipment.

Practical recommendation

LDPE is suitable for use with Formaldehyde Solution under normal conditions, but some minor effects on the material are expected over time. Periodic monitoring for swelling, softening, or weight change is recommended, especially for long-service components. Avoid prolonged exposure at elevated temperatures, as the resistance decreases further at 50 °C. For safety-critical or long-life applications, consider HDPE, Nylon (PA), Polycarbonate instead, which are rated A for this chemical.

Did you know?

In industrial practice, LDPE components exposed to Formaldehyde Solution are typically inspected for swelling, discoloration, or loss of mechanical strength as early indicators of chemical attack.

Materials rated A or B at 20 °C

Based on the row for 40 %, 20 °C.

Thermoplastics
HDPE A, PP A, PVC Rigid B, Nylon (PA) A, Acetal (POM) A, Polycarbonate A, Polysulfone B, PETG A, PMP A
Fluoropolymers
PTFE A, PVDF A, FEP A, ECTFE/ETFE A
Elastomers
EPDM A
Metals
SS 316 A, SS 304 A, Aluminium A

About LDPE

Low-density polyethylene has a similar profile to HDPE but is softer and more permeable, so solvents swell it sooner. Continuous service is usually limited to about 60 °C.

Rating scale

A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.

About this data

The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.

A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.