Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| technical grade | C | C |
Material comparison at 20 °C
Resistance overview
PVC Rigid has limited resistance (C) to Lanolin at technical grade at 20 °C. This indicates that the chemical has a noticeable effect on the material, which may include visible swelling, softening, or a measurable loss of tensile strength. Use is generally limited to short-term or intermittent contact where full structural integrity is not required. The rating remains stable between 20 °C and 50 °C, which means this material can also handle moderately elevated process temperatures without additional risk.
Application context
Lanolin is commonly encountered in de-icing and chemical storage. PVC Rigid (Rigid (unplasticised) polyvinyl chloride) is a thermoplastic typically used for tanks, piping, containers and liners. The compatibility between these two is therefore an important consideration for engineers and procurement teams selecting containment, transfer, or processing equipment.
Practical recommendation
PVC Rigid has limited resistance to Lanolin and should only be used for short-term or intermittent contact at ambient temperature. The C rating means the material undergoes noticeable changes — swelling, loss of strength, or surface degradation — that make it unsuitable for permanent installations. For prolonged or continuous exposure, Nylon (PA), Polycarbonate, PETG offer significantly better resistance and are rated A.
Did you know?
The ratings shown here apply to pure Lanolin in contact with the base thermoplastic. In real-world applications, additives, pigments, and fillers in the material can shift resistance in either direction.
Materials rated A or B at 20 °C
Based on the row for technical grade, 20 °C.
- Thermoplastics
- Nylon (PA) A, Acetal (POM) B, Polycarbonate A, Polystyrene A, PETG A, SAN A
- Fluoropolymers
- PTFE A, PVDF A, FEP A
- Elastomers
- Viton (FPM) A, NBR A
- Metals
- SS 316 A, SS 304 A, Aluminium A
About PVC Rigid
Rigid PVC resists acids, alkalis and salt solutions well. Ketones, esters, aromatic and chlorinated solvents dissolve or swell it. Service temperature is limited to about 60 °C.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.