ChemicalResistance
ChemicalResistance.org

SAN and Phosphoric Acid: Chemical Resistance

Styrene-acrylonitrile

Rating

Concentration20 °C50 °CRemark
1-5 %AA
20 %––
30 %AA
85 %AB

Material comparison at 20 °C

Phosphoric Acid: Material comparison at 20 °CSAN: A (highlighted); ECTFE/ETFE: A; FEP: A; Viton (FPM): A; HDPE: A; LDPE: A.ECTFE/ETFE: AFEP: AViton (FPM): AHDPE: ALDPE: APolycarbonate: APMP: APP: APolystyrene: APolysulfone: APTFE: APVC Rigid: APVC Flexible: APVDF: ASAN: ASANSS 316: ASS 304: BEPDM: CAluminium: DNBR: DNylon (PA): DAcetal (POM): DPETG: –Silicone: –
A very good resistanceB good resistanceC limited resistanceD not resistantno data
Each bar is one material. Taller bars indicate better resistance. The highlighted bar is the current material.

Resistance overview

SAN shows excellent resistance to Phosphoric Acid across all 3 tested concentrations (1-5 %, 30 %, 85 %) at 20 °C, making it a reliable choice for storage, transfer, and handling applications involving this chemical at any of the tested strengths. However, at 50 °C the resistance rating drops, indicating that temperature must be factored into the design. For heated applications, additional testing under actual service conditions is strongly recommended.

Application context

Phosphoric Acid is commonly encountered in chemical processing and surface cleaning. SAN (Styrene-acrylonitrile) is a thermoplastic typically used for tanks, piping, containers and liners. Because Phosphoric Acid is classified as corrosive, the choice of containment material is especially critical to prevent leaks, equipment damage, and safety hazards.

Practical recommendation

SAN can be used with confidence for Phosphoric Acid containment and handling. The A rating indicates that the material shows no significant change in weight, dimensions, or mechanical properties after prolonged contact under test conditions. At elevated temperatures (50 °C), some reduction in resistance occurs, so periodic inspection is advisable for heated applications. Always verify performance under actual operating conditions before committing to a design.

Did you know?

In industrial practice, SAN components exposed to Phosphoric Acid are typically inspected for swelling, discoloration, or loss of mechanical strength as early indicators of chemical attack.

Materials rated A or B at 20 °C

Based on the row for 85 %, 20 °C.

Thermoplastics
HDPE A, PP A, PVC Rigid A, LDPE A, Polycarbonate A, PVC Flexible A, Polystyrene A, Polysulfone A, PMP A
Fluoropolymers
PTFE A, PVDF A, FEP A, ECTFE/ETFE A
Elastomers
Viton (FPM) A
Metals
SS 316 A, SS 304 B

About SAN

Styrene-acrylonitrile resists oils and dilute acids better than polystyrene, but ketones, esters and aromatic and chlorinated solvents still attack it.

Rating scale

A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.

About this data

The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.

A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.