Rating
| Concentration | 20 °C | 50 °C | Remark |
|---|---|---|---|
| aqueous | A | – | |
| saturated | A | – |
Material comparison at 20 °C
Resistance overview
Acetal (POM) shows excellent resistance to Calcium Hypochlorite across all 2 tested concentrations (aqueous, saturated) at 20 °C, making it a reliable choice for storage, transfer, and handling applications involving this chemical at any of the tested strengths. The rating remains stable between 20 °C and 50 °C, which means this material can also handle moderately elevated process temperatures without additional risk.
Application context
Calcium Hypochlorite is commonly encountered in bleaching and pulp and paper. Acetal (POM) (Polyoxymethylene (acetal)) is a thermoplastic typically used for tanks, piping, containers and liners. Because Calcium Hypochlorite is classified as corrosive, the choice of containment material is especially critical to prevent leaks, equipment damage, and safety hazards.
Practical recommendation
Acetal (POM) can be used with confidence for Calcium Hypochlorite containment and handling. The A rating indicates that the material shows no significant change in weight, dimensions, or mechanical properties after prolonged contact under test conditions. This holds true at both 20 °C and 50 °C, giving a good safety margin for typical process environments.
Did you know?
Polyoxymethylene (acetal) was first developed in the 1950s and remains one of the most widely used thermoplastics in chemical handling equipment.
Materials rated A or B at 20 °C
Based on the row for saturated, 20 °C.
- Thermoplastics
- HDPE A, PP A, PVC Rigid B, LDPE A, Nylon (PA) A, Polystyrene B, Polysulfone A, PMP A, SAN A
- Fluoropolymers
- PTFE A, PVDF A, FEP A, ECTFE/ETFE A
- Elastomers
- EPDM B, Viton (FPM) B
- Metals
- SS 316 B
About Acetal (POM)
Acetal (POM) resists many organic solvents and fuels. Strong acids and oxidising agents degrade it.
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.