Compatibility Rating
📊 Note: Hydrochloric Acid resistance varies by concentration. Data available for: 1-5 %, 20 %, 35 %. Search for specific concentrations →
Why is Viton (FPM) resistant to Hydrochloric Acid?
Viton (FPM) shows excellent resistance to Hydrochloric Acid due to its fluorinated rubber structure providing exceptional resistance to oils, fuels, and many chemicals.
⚠️ When NOT to use Viton (FPM)
Avoid using Viton Fluoroelastomer with ketones, esters, amines, and hot water/steam. Excellent for fuel and oil applications.
Comparison Table — All Materials for Hydrochloric Acid
| Material | 20°C | 50°C |
|---|---|---|
| HDPE | A | A |
| LDPE | A | A |
| PP | A | A |
| PTFE | A | A |
| PVDF | A | A |
| FEP | A | A |
| ECTFE/ETFE | A | A |
| EPDM | A | NR |
| Viton (FPM) | A | A |
| NBR | D | D |
| Silicone | NR | NR |
| SS 316 | D | D |
| SS 304 | D | D |
| Aluminium | D | D |
| PVC Rigid | A | C |
| PVC Flexible | NR | NR |
| PMP | A | B |
| Polystyrene | A | A |
| SAN | NR | NR |
| Polycarbonate | B | C |
| PETG | C | NR |
| Acetal (POM) | D | D |
| Nylon (PA) | D | D |
| Polysulfone | A | A |
A=Excellent · B=Good · C=Fair · D=Poor · NR=No Data