ChemicalResistance
ChemicalResistance.org

Polysulfone and Sodium Hypochlorite (Bleach): Chemical Resistance

Polysulfone

Rating

Concentration20 °C50 °CRemark
12,5 % ClAA
15 %AA
diluteAA
saturatedAA

Material comparison at 20 °C

Sodium Hypochlorite (Bleach): Material comparison at 20 °CPolysulfone: A (highlighted); ECTFE/ETFE: A; FEP: A; Viton (FPM): A; PMP: A; Polystyrene: A.ECTFE/ETFE: AFEP: AViton (FPM): APMP: APolystyrene: APolysulfone: APSUPTFE: APVC Rigid: ASAN: AHDPE: BLDPE: BPolycarbonate: BPP: BSS 316: BEPDM: CPETG: CPVDF: CSS 304: CAluminium: DNBR: DNylon (PA): DAcetal (POM): DPVC Flexible: –Silicone: –
A very good resistanceB good resistanceC limited resistanceD not resistantno data
Each bar is one material. Taller bars indicate better resistance. The highlighted bar is the current material.

Resistance overview

Polysulfone shows excellent resistance to Sodium Hypochlorite (Bleach) across all 4 tested concentrations (12,5 % Cl, 15 %, dilute, saturated) at 20 °C, making it a reliable choice for storage, transfer, and handling applications involving this chemical at any of the tested strengths. The rating remains stable between 20 °C and 50 °C, which means this material can also handle moderately elevated process temperatures without additional risk.

Application context

Sodium Hypochlorite (Bleach) is commonly encountered in water disinfection and waste treatment. Polysulfone (Polysulfone) is a thermoplastic typically used for tanks, piping, containers and liners. Because Sodium Hypochlorite (Bleach) is classified as corrosive, the choice of containment material is especially critical to prevent leaks, equipment damage, and safety hazards.

Practical recommendation

Polysulfone can be used with confidence for Sodium Hypochlorite (Bleach) containment and handling. The A rating indicates that the material shows no significant change in weight, dimensions, or mechanical properties after prolonged contact under test conditions. This holds true at both 20 °C and 50 °C, giving a good safety margin for typical process environments.

Did you know?

In industrial practice, Polysulfone components exposed to Sodium Hypochlorite (Bleach) are typically inspected for swelling, discoloration, or loss of mechanical strength as early indicators of chemical attack.

Materials rated A or B at 20 °C

Based on the row for 15 %, 20 °C.

Thermoplastics
HDPE B, PP B, PVC Rigid A, LDPE B, Polycarbonate B, Polystyrene A, PMP A, SAN A
Fluoropolymers
PTFE A, FEP A, ECTFE/ETFE A
Elastomers
Viton (FPM) A
Metals
SS 316 B

About Polysulfone

Polysulfone withstands hot water and steam. Ketones, esters and chlorinated and aromatic solvents attack it.

Rating scale

A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.

About this data

The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.

A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.