At a glance
Based on the row for 90 %, 20 °C.
- Rated A, very good resistance
- PTFE, HDPE, PP, PVDF, PVC Rigid, Viton (FPM), SS 316, SS 304, LDPE, FEP, ECTFE/ETFE, Polycarbonate, Polystyrene, Polysulfone, PMP (15)
- Rated B, good resistance
- none (0)
- Rated C, limited resistance
- EPDM, Aluminium (2)
- Rated D, not resistant
- NBR, Nylon (PA), Acetal (POM) (3)
- No data in the source
- Silicone, PVC Flexible, PETG, SAN
- Rated lower at 50 °C than at 20 °C
- PP (A → B), PVC Rigid (A → B), Viton (FPM) (A → C), LDPE (A → B), Polystyrene (A → B), PMP (A → B)
- Rating changes with concentration (20 °C)
- PP: A (3 %), D (100 %); PVDF: A (3 %), B (100 %); EPDM: A (3 %), C (30 %); Viton (FPM): A (3 %), B (100 %); NBR: C (3 %), D (30 %); Nylon (PA): C (3 %), D (30 %); Acetal (POM): A (3 %), D (30 %); Polystyrene: A (3 %), D (100 %)
Based on the row for 90 %, 20 °C.
Rating profile by material family
Effect of temperature, 20 °C to 50 °C
Substance
- CAS number
- 7722-84-1
- Formula
- H2O2
- Hazard symbols in the source
- C (corrosive) (pre-GHS European symbols; check the current safety data sheet)
- Concentrations listed
- 3 %; 30 %; 90 %; 100 %
- Name in the source (German)
- Wasserstoffperoxid
Rating by concentration
Show as a table
| Material | 3 % | 30 % | 90 % | 100 % |
|---|---|---|---|---|
| Thermoplastics | ||||
| HDPE | A | A | A | A |
| LDPE | A | A | A | A |
| PP | A | A | A | D |
| PVC Rigid | A | A | A | – |
| PVC Flexible | – | – | – | – |
| PMP | A | A | A | – |
| Polystyrene | A | A | A | D |
| SAN | A | A | – | – |
| Polycarbonate | A | A | A | – |
| PETG | A | A | – | – |
| Acetal (POM) | A | D | D | D |
| Nylon (PA) | C* | D | D | D |
| Polysulfone | A | A | A | – |
| Fluoropolymers | ||||
| PTFE | A | A | A | A* |
| FEP | A | A | A | A* |
| PVDF | A | A | A | B* |
| ECTFE/ETFE | A | A | A | – |
| Elastomers | ||||
| EPDM | A | C | C | C* |
| Viton (FPM) | A | A | A | B* |
| NBR | C | D | D | D |
| Silicone | – | – | – | – |
| Metals | ||||
| SS 316 | A | A | A | A* |
| SS 304 | A | A | A | A* |
| Aluminium | C* | C* | C* | C* |
* estimated rating, given in the source without a temperature
Resistance table: Hydrogen Peroxide, 3 %
| Material | 20 °C | 50 °C | Remark |
|---|---|---|---|
| Thermoplastics | |||
| HDPE | A | A | |
| LDPE | A | A | |
| PP | A | A | |
| PVC Rigid | A | A | |
| PMP | A | A | |
| Polystyrene | A | B | |
| SAN | A | A | |
| Polycarbonate | A | A | |
| PETG | A | – | |
| Acetal (POM) | A | – | disputed, see below |
| Nylon (PA) | C* | – | |
| Polysulfone | A | A | |
| Fluoropolymers | |||
| PTFE | A | A | |
| FEP | A | A | |
| PVDF | A | A | |
| ECTFE/ETFE | A | A | |
| Elastomers | |||
| EPDM | A | – | |
| Viton (FPM) | A | – | |
| NBR | C | D | |
| Metals | |||
| SS 316 | A | A | |
| SS 304 | A | A | |
| Aluminium | C* | – | |
* estimated rating, given in the source without a temperature
Not rated in the source, so not in the table: PVC Flexible, Silicone
Resistance table: Hydrogen Peroxide, 30 %
| Material | 20 °C | 50 °C | Remark |
|---|---|---|---|
| Thermoplastics | |||
| HDPE | A | A | |
| LDPE | A | B | |
| PP | A | C | |
| PVC Rigid | A | A | |
| PMP | A | B | |
| Polystyrene | A | B | |
| SAN | A | – | |
| Polycarbonate | A | A | |
| PETG | A | – | |
| Acetal (POM) | D | D | |
| Nylon (PA) | D | D | |
| Polysulfone | A | A | |
| Fluoropolymers | |||
| PTFE | A | A | |
| FEP | A | A | |
| PVDF | A | A | |
| ECTFE/ETFE | A | A | |
| Elastomers | |||
| EPDM | C | – | |
| Viton (FPM) | A | A | |
| NBR | D | D | |
| Metals | |||
| SS 316 | A | A | |
| SS 304 | A | A | |
| Aluminium | C* | – | |
* estimated rating, given in the source without a temperature
Not rated in the source, so not in the table: PVC Flexible, Silicone
Resistance table: Hydrogen Peroxide, 90 %
| Material | 20 °C | 50 °C | Remark |
|---|---|---|---|
| Thermoplastics | |||
| HDPE | A | A | |
| LDPE | A | B | |
| PP | A | B | |
| PVC Rigid | A | B | |
| PMP | A | B | |
| Polystyrene | A | B | |
| Polycarbonate | A | A | |
| Acetal (POM) | D | D | |
| Nylon (PA) | D | D | |
| Polysulfone | A | A | |
| Fluoropolymers | |||
| PTFE | A | A | |
| FEP | A | A | |
| PVDF | A | – | |
| ECTFE/ETFE | A | A | |
| Elastomers | |||
| EPDM | C | – | |
| Viton (FPM) | A | C | |
| NBR | D | D | |
| Metals | |||
| SS 316 | A | A | |
| SS 304 | A | A | |
| Aluminium | C* | – | |
* estimated rating, given in the source without a temperature
Not rated in the source, so not in the table: PVC Flexible, SAN, PETG, Silicone
Resistance table: Hydrogen Peroxide, 100 %
| Material | 20 °C | 50 °C | Remark |
|---|---|---|---|
| Thermoplastics | |||
| HDPE | A | D | |
| LDPE | A | D | |
| PP | D | D | |
| Polystyrene | D | D | |
| Acetal (POM) | D | D | |
| Nylon (PA) | D | D | |
| Fluoropolymers | |||
| PTFE | A* | – | |
| FEP | A* | – | |
| PVDF | B* | – | |
| Elastomers | |||
| EPDM | C* | – | |
| Viton (FPM) | B* | – | |
| NBR | D | D | |
| Metals | |||
| SS 316 | A* | – | |
| SS 304 | A* | – | |
| Aluminium | C* | – | |
* estimated rating, given in the source without a temperature
Not rated in the source, so not in the table: PVC Rigid, PVC Flexible, PMP, SAN, Polycarbonate, PETG, Polysulfone, ECTFE/ETFE, Silicone
Rating scale
- A very good resistance
- B good resistance
- C limited resistance
- D not resistant
- – no data
- K no general statement possible
A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.
Corrected and disputed values
- Acetal (POM) (3 %): source value 1/0 kept, but other published charts rate it lower. Two charts that share one data set rate acetal D for dilute hydrogen peroxide. The source itself rates acetal D from 30 %. [1] [2]
Source values use the scale 1 (very good) to 4 (not resistant); 1 = A, 4 = D.
Frequently Asked Questions
Which materials resist Hydrogen Peroxide at high concentrations?
The materials with an A rating (resistant) for Hydrogen Peroxide at 20 °C are: PTFE, HDPE, PP, PVDF, PVC Rigid, Viton (FPM), SS 316, SS 304. These can generally be used in direct contact.
Which materials should be avoided with Hydrogen Peroxide?
Materials rated D (not resistant) for Hydrogen Peroxide are: NBR, Nylon (PA), Acetal (POM). These should not be used in contact with Hydrogen Peroxide.
Does temperature affect chemical resistance to Hydrogen Peroxide?
Yes. 6 of 17 tested materials show a worse rating at 50 °C than at 20 °C for Hydrogen Peroxide. Materials affected include: PP, PVC Rigid, Viton (FPM), LDPE, Polystyrene, PMP.
Is PTFE safe for Hydrogen Peroxide?
PTFE is rated A for Hydrogen Peroxide at 20 °C. A rating of A means resistant, B means limited resistance, C means partly resistant, and D means not resistant.
Does concentration affect chemical resistance to Hydrogen Peroxide?
Yes. Hydrogen Peroxide is tested at 4 concentrations (3 %, 30 %, 90 %, 100 %). Some materials change their rating depending on the concentration.
About this data
The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.
A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.
Chemicals with a similar resistance profile
Same 20 °C rating on the share of materials shown.