ChemicalResistance
ChemicalResistance.org

PVC Rigid vs Silicone: Chemical Resistance Compared

Of 21 source rows rated for both materials at 20 °C, 21 (100 %) have the same rating. PVC Rigid is rated better in 0 rows and Silicone in 0. A row is one chemical at one concentration.

Summary

Within 10 points of each other
Salts and salt solutions

Points are the difference in the share of rows rated A or B.

The two materials

PVC Rigid

Rigid (unplasticised) polyvinyl chloride

Rigid PVC resists acids, alkalis and salt solutions well. Ketones, esters, aromatic and chlorinated solvents dissolve or swell it. Service temperature is limited to about 60 °C.

Rated rows: 569. A 62 %, B 8 %, C 9 %, D 21 %

All chemicals for PVC Rigid

Silicone

Silicone rubber

Silicone rubber keeps its flexibility over a wide temperature range. Concentrated acids and alkalis and hydrocarbon solvents attack or swell it.

Rated rows: 23. A 96 %, B 0 %, C 0 %, D 4 %

All chemicals for Silicone

Share of rows rated A or B, by chemical class

PVC Rigid, Silicone: Share of rows rated A or B, by chemical classSalts and salt solutions: PVC Rigid 100 %, Silicone 100 %.Salts and salt solutionsSalts and salt solutions, PVC Rigid: 100 % (111)100 %Salts and salt solutions, Silicone: 100 % (9)100 %
PVC RigidSilicone
Rating at 20 °C. Only classes with at least 8 rated rows for both materials are shown.

How often the two ratings agree

PVC Rigid, Silicone: How often the two ratings agreePVC Rigid A, Silicone A: 21.SiliconeABCDPVC RigidAPVC Rigid A, Silicone A: 2121PVC Rigid A, Silicone B: 00PVC Rigid A, Silicone C: 00PVC Rigid A, Silicone D: 00BPVC Rigid B, Silicone A: 00PVC Rigid B, Silicone B: 00PVC Rigid B, Silicone C: 00PVC Rigid B, Silicone D: 00CPVC Rigid C, Silicone A: 00PVC Rigid C, Silicone B: 00PVC Rigid C, Silicone C: 00PVC Rigid C, Silicone D: 00DPVC Rigid D, Silicone A: 00PVC Rigid D, Silicone B: 00PVC Rigid D, Silicone C: 00PVC Rigid D, Silicone D: 00
Number of source rows for each pair of ratings at 20 °C. Outlined cells are rows where both materials have the same rating.

Chemical classes were assigned by this site, not by the source. Mixtures and trade products without a clear class are not counted.

By chemical class

Chemical classPVC Rigid: rated A or BSilicone: rated A or B
Mineral acids82 % (56 rows)–
Organic acids87 % (45 rows)–
Alkalis100 % (16 rows)–
Salts and salt solutions100 % (111 rows)100 % (9 rows)
Oxidising agents and halogens85 % (39 rows)–
Alcohols and glycols79 % (43 rows)–
Phenols38 % (8 rows)–
Ketones and aldehydes11 % (18 rows)–
Esters and ethers5 % (39 rows)–
Amines and nitrogen compounds23 % (22 rows)–
Aromatic hydrocarbons0 % (9 rows)–
Fuels, mineral oils and aliphatic hydrocarbons84 % (38 rows)–
Vegetable and animal oils, fats, essential oils59 % (17 rows)–
Halogenated hydrocarbons8 % (36 rows)–
Foods and beverages100 % (23 rows)–

Where the ratings differ most

No row has ratings more than one grade apart.

Rating scale

A rating marked * is an estimate in the source, not a test result. An estimate is given as one value without a temperature.

More comparisons

Frequently Asked Questions

Is PVC Rigid or Silicone more chemical-resistant?

Of 21 chemicals rated for both materials at 20 °C, PVC Rigid and Silicone share the same rating in 21 rows (100 %). PVC Rigid is rated better in 0 rows and Silicone in 0 rows.

How do PVC Rigid and Silicone compare for chemical resistance?

Based on 21 chemicals tested for both: PVC Rigid is rated better with –. Silicone is rated better with –. They perform similarly with Salts and salt solutions.

About this data

The ratings come from the chemical resistance list published by Bürkle GmbH, which compiled them from raw-material manufacturers’ data. They describe laboratory tests on the raw material at 20 °C and 50 °C.

A finished part also sees pressure, mechanical stress, welds and mixtures that a laboratory test does not. Treat the rating as a first filter and test under your own conditions before relying on it.